Pliki do pobrania

ECOCONDENS CRYSTAL II PLUS

A
      
ECOCONDENS CRYSTAL II PLUS gas condensing boilers are intended for heating small and large areas. Their characteristic feature is the ability to achieve a very wide range of modulation, e. g. thanks to the innovative BLUEJET burner, which allows to reduce the minimum power up to 3 kW. Stainless steel heat exchanger guarantees high energy efficiency and economical boiler operation. Control system enables comfortable remote control of the boiler by user and monitoring operation of the device by service personnel via laptop.
  • heat exchanger made of stainless steel
  • wide range of modulation: from 11% to 100%
  • high efficiency circulation pump
  • stepless speed regulation fan (controlled electronically)
  • cylinder burner made of stainless steel – low level of NOx emission (6th class)
  • complete protection system
  • optimization of boiler operation is possible due to application of:
    • outdoor temperature sensor
    • temperature regulator: ON/OFF, Open-Therm or 0-10V,
    • ROUND system for remote boiler control via smartphone,
    • EVOHOME system for remote control of up to 11 heating zones
    • ready-to-use multi-zone modules for controlling up to 3 SIM heating systems
  • boilers can also cooperate with:
    • heat pumps air/water
    • solar panels
    • domestic hot water cylinder by 3-way valve (concerns system boilers)
Parametry Wartość
Thermal power (at temp. 80/60°C) 2,7-20,0 kW
Thermal power (at temp. 50/30°C) 3,0-22,0 kW
Heat load 2,8-20,4 kW
Seasonal space heating energy efficiency ηs 93 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
97,6 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
107,9 %
Seasonal space heating energy efficiency class A
Useful heat output at rated thermal power P4 (for modulated
boilers - arithmetic mean of min and max)
20,0 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers - 30% of arithmetic mean)
6,6 kW
Efficiency η4 88,0 %
Efficiency η1 98,0 %
Max water pressure 3 bar
Max CH temperature 95 °C
Standard adjustable temperature 20-80 °C
Pump head at 0 flow 0,7 bar
Range of water temperature regulation 30-60 °C
Sound power level LWA 48 dB
Emission of nitrogen dioxide 21 mg/kWh
Emission class of nitrogen dioxide (NOx) 6
Expansion vessel capacity 6 dm³
Standby mode power consumption PSB 0,003 kW
Electricity consumption at full load elmax 0,06 kW
Electricity consumption at partial load elmax 0,02 kW
Type and supply voltage ~230-10%/50Hz V
Protection degree IPX4D
Heating water and gas connection G3/4 inch
Dimensions 777x400x285 mm
Weight 32 kg
Parametry Wartość
Thermal power (at temp. 80/60°C) 3,9-24,0 kW
Thermal power (at temp. 50/30°C) 4,3-26,5 kW
Heat load 4,0-24,6 kW
Seasonal space heating energy efficiency ηs 94 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
98 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
108,7 %
Seasonal space heating energy efficiency class A
Useful heat output at rated thermal power P4 (for modulated
boilers - arithmetic mean of min and max)
24,0 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers - 30% of arithmetic mean)
7,9 kW
Efficiency η4 88,0 %
Efficiency η1 98,8 %
Max water pressure 3 bar
Max CH temperature 95 °C
Standard adjustable temperature 20-80 °C
Pump head at 0 flow 0,7 bar
Range of water temperature regulation 30-60 °C
Sound power level LWA 48 dB
Emission of nitrogen dioxide 24 mg/kWh
Emission class of nitrogen dioxide (NOx) 6
Expansion vessel capacity 6 dm³
Standby mode power consumption PSB 0,001 kW
Electricity consumption at full load elmax 0,07 kW
Electricity consumption at partial load elmax 0,04 kW
Type and supply voltage ~230-10%/50Hz V
Protection degree IPX4D
Heating water and gas connection G3/4 inch
Dimensions 777x400x285 mm
Weight 34,0 kg
Parametry Wartość
Thermal power (at temp. 80/60°C) 8,4-34,9 kW
Thermal power (at temp. 50/30°C) 9,4-38,8 kW
Heat load 8,6-35,6 kW
Seasonal space heating energy efficiency ηs 95 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
98,0 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
109,0 %
Seasonal space heating energy efficiency class A
Useful heat output at rated thermal power P4 (for modulated
boilers - arithmetic mean of min and max)
34,9 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers - 30% of arithmetic mean)
11,5 kW
Efficiency η4 88,0 %
Efficiency η1 99,8 %
Max water pressure 3 bar
Max CH temperature 95 °C
Standard adjustable temperature 20-80 °C
Pump head at 0 flow 0,7 bar
Range of water temperature regulation 30-60 °C
Sound power level LWA 48 dB
Emission of nitrogen dioxide 29 mg/kWh
Emission class of nitrogen dioxide (NOx) 6
Expansion vessel capacity 6 dm³
Standby mode power consumption PSB 0,001 kW
Electricity consumption at full load elmax 0,09 kW
Electricity consumption at partial load elmax 0,05 kW
Type and supply voltage ~230-10%/50Hz V
Protection degree IPX4D
Heating water and gas connection G3/4 inch
Dimensions 777x400x285 mm
Weight 36 kg