Files to download
SILVER PRO
A
Gas condensing boilers line SILVER PRO – one of the most modern and smallest devices in the European market. Thanks to transparent control panel these boilers are very easy to use. Advanced design and compact sizes make them fit in every kitchen and other rooms as well. Wide range of modulation allows the boilers to heat very small areas and objects with low heat demand. Devices are adapted to work with solar systems, heat pumps and multi-zone hydraulic separators.
- energy class: A
- heat exchanger with one coil made of stainless steel
- wide modulation range: from 12 to 100%
- OPEN-THERM system by EASY REMOTE regulator
- electronically controlled modulating fan
- cylinder burner made of stainless steel – low level of NOx emission (class 6)
- hydraulic group (hydroblock) assembled on quick-connector
- complete protection system
- works with multi-zone hydraulic separators for heating systems
- works with heat pumps air/water
- additional noise insulation provides quiet operation of the boiler (only 48 dB)
- works with solar panels
- high efficiency circulation pump
- works with domestic hot water cylinder by 3-way valve
Parameters | Value |
Thermal power (at temp. 80/60°C) | 2,7 - 20,0 kW |
Thermal power (at temp. 50/30°C) | 3,0 - 22,0 kW |
Heat load | 2,8 - 20,4 kW |
Seasonal space heating energy efficiency ηs | 95 % |
Efficiency of the boiler at nominal load and average boiler water temperature of 70°C |
97,6 % |
Efficiency of the boiler at partial load and return water temperature of 30°C |
107,9 % |
Seasonal space heating energy efficiency class | A |
Useful heat output at rated thermal power P4 (for modulated boilers - arithmetic mean of min and max) |
20,0 kW |
Useful heat output at 30% of rated power P1 (for modulated boilers - 30% of arithmetic mean) |
6,6 kW |
Efficiency η4 | 88,6 % |
Efficiency η1 | 100,0 % |
Max water pressure | 3 bar |
Max CH temperature | 95 °C |
Standard adjustable temperature | 40-80 °C |
Reduced adjustable temperature | 25-55 °C |
Pump head at 0 flow | 0,7 bar |
Range of water temperature regulation | 30-60 °C |
Sound power level LWA | 48 dB |
Emission of nitrogen dioxide | 21 mg/kWh |
Emission class of nitrogen dioxide (NOx) | 6 |
Expansion vessel capacity | 6 dm³ |
Standby mode power consumption PSB | 0,002 kW |
Electricity consumption at full load elmax | 0,06 kW |
Electricity consumption at partial load elmax | 0,07 kW |
Type and supply voltage | ~230±10%/50Hz V |
Protection degree | IPX4D |
Heating water and gas connection | G3/4 inch |
Dimensions | 785 x 400 x 334 mm |
Weight | 32,0 kg |
Exchanger material | stainless steel |
Parameters | Value |
Thermal power (at temp. 80/60°C) | 3,9 - 24,0 kW |
Thermal power (at temp. 50/30°C) | 4,3 - 26,5 kW |
Heat load | 4,0 - 24,6 kW |
Seasonal space heating energy efficiency ηs | 93 % |
Efficiency of the boiler at nominal load and average boiler water temperature of 70°C |
98,0 % |
Efficiency of the boiler at partial load and return water temperature of 30°C |
108,7 % |
Seasonal space heating energy efficiency class | A |
Useful heat output at rated thermal power P4 (for modulated boilers - arithmetic mean of min and max) |
24,0 kW |
Useful heat output at 30% of rated power P1 (for modulated boilers - 30% of arithmetic mean) |
7,9 kW |
Efficiency η4 | 88,4 % |
Efficiency η1 | 97,3 % |
Max water pressure | 3 bar |
Max CH temperature | 95 °C |
Standard adjustable temperature | 40-80 °C |
Reduced adjustable temperature | 25-55 °C |
Pump head at 0 flow | 0,7 bar |
Range of water temperature regulation | 30-60 °C |
Sound power level LWA | 48 dB |
Emission of nitrogen dioxide | 24 mg/kWh |
Emission class of nitrogen dioxide (NOx) | 6 |
Expansion vessel capacity | 6 dm³ |
Standby mode power consumption PSB | 0,003 kW |
Electricity consumption at full load elmax | 0,07 kW |
Electricity consumption at partial load elmax | 0,06 kW |
Type and supply voltage | ~230±10%/50Hz V |
Protection degree | IPX4D |
Heating water and gas connection | G3/4 inch |
Dimensions | 785 x 400 x 334 mm |
Weight | 34,0 kg |
Exchanger material | stainless steel |
Parameters | Value |
Thermal power (at temp. 80/60°C) | 4,1 - 34,7 kW |
Thermal power (at temp. 50/30°C) | 4,5 - 38,2 kW |
Heat load | 4,2 - 35,6 kW |
Seasonal space heating energy efficiency ηs | 95 % |
Efficiency of the boiler at nominal load and average boiler water temperature of 70°C |
98,0 % |
Efficiency of the boiler at partial load and return water temperature of 30°C |
109,0 % |
Seasonal space heating energy efficiency class | A |
Useful heat output at rated thermal power P4 (for modulated boilers - arithmetic mean of min and max) |
34,7 kW |
Useful heat output at 30% of rated power P1 (for modulated boilers - 30% of arithmetic mean) |
11,5 kW |
Efficiency η4 | 88,4 % |
Efficiency η1 | 99,4 % |
Max water pressure | 3 bar |
Max CH temperature | 95 °C |
Standard adjustable temperature | 40-80 °C |
Reduced adjustable temperature | 25-55 °C |
Pump head at 0 flow | 0,7 bar |
Range of water temperature regulation | 30-60 °C |
Sound power level LWA | 48 dB |
Emission of nitrogen dioxide | 29 mg/kWh |
Emission class of nitrogen dioxide (NOx) | 6 |
Expansion vessel capacity | 6 dm³ |
Standby mode power consumption PSB | 0,003 kW |
Electricity consumption at full load elmax | 0,09 kW |
Electricity consumption at partial load elmax | 0,05 kW |
Type and supply voltage | ~230±10%/50Hz V |
Protection degree | IPX4D |
Heating water and gas connection | G3/4 inch |
Dimensions | 785 x 400 x 334 mm |
Weight | 36,0 kg |
Exchanger material | stainless steel |
The manufacturer reserves the right to change the device’s structure which do not have a significant impact on functional and technical characteristics of a product.