ECOCONDENS CRYSTAL -100
ECOCONDENS CRYSTAL 100 wall mounted gas condensing boilers are intended for heating large objects such as: multifamily buildings, boarding houses or office buildings. Boilers can work as independent units as well as in a cascade system. The modern control system used in the boiler allows to combine up to 6 boilers into a cascade without the need for an additional cascade manager and to achieve a total output of up to 600 kW.
- innovative heat exchanger design makes the boilers small in size in relation to their power output,
- high efficiency circulation pump (EEI ≤ 0,23),
- venting of the boiler is carried out by an air-vent mounted on the exchanger,
- electronically controlled modulating fan which ensures low energy consumption,
- burner with a wide range of modulation which ensures low NOx emissions (5th Class),
- two preinstalled adapters with measuring points: Ø100 air and Ø100 exhaust gas,
- NTC sensor of hydraulic coupling on the boiler equipment,
- Open-Therm communication protocol,
- works with domestic hot water cylinders with a coil output of min. 25 kW,
- in cascade systems, boilers are connected in series via a wire connected to the boiler. First boiler works as MASTER boiler (it functions as a manager), others work as a subordinate SLAVE, so there is no need to connect an additional external manager,
- high efficiency circulation pump with a lifting height of 8m; boiler version with pump of 12m lifting height available on request.
Parameters | Value |
Thermal power (at temp. 80/60°C) | 17,0 - 100,0 kW |
Thermal power (at temp. 50/30°C) | 19,0 - 110,0 kW |
Heat load | 18,0 - 103,0 kW |
Efficiency of the boiler at nominal load and average boiler water temperature of 70°C |
97,0 % |
Efficiency of the boiler at partial load and return water temperature of 30°C |
107,0 % |
Efficiency η4 | 87 % |
Efficiency η1 | 95 % |
Max water pressure | 4 bar |
Standard adjustable temperature | 20 - 80 °C |
Pump head at 0 flow | 0,8 bar |
Sound power level LWA | 65 dB |
Emission of nitrogen dioxide | ≤ 50 mg/kWh |
Emission class of nitrogen dioxide (NOx) | 5 |
Max. amount of condensate (natural gas) | 15 l/h |
Type and supply voltage | ~ 230 ±10%/ 50Hz V |
Protection degree | IPX4D |
Connection to the chimney duct | 2 x ø100 |
Heating water and gas connection | G 5/4 -- G 1 inch |
Dimensions | 810 x 540 x 545 mm |
Weight | 84 kg |
Exchanger material | stainless steel |
The manufacturer reserves the right to change the device’s structure which do not have a significant impact on functional and technical characteristics of a product.